12 Myson, Inc. • 800-698-9690 • www.MysonInc.com
Kickspace Fan Convector Installation
MYSON EZ-Hose Kit
1. A kickspace heater must have a free flow of air through the unit. We have designed our grills to allow for sufficient
airflow. The opening in the kickspace must allow unrestricted airflow. (See drawing below.) Looking at the grill,
you should not be able to see any part of the kickboard. Failure to do so will cause the motor to overheat and
void the warranty.
2. The kickspace heater needs to be sized appropriately for the job. For proper sizing, use the ratings at normal speed.
If the unit needs to be in the boost or high setting to heat the room adequately, then the kickspace heater is too
small. Running the unit in boost or high for extended periods of time will shorten the motor fan assembly life.
The MYSON EZ-Hose Kit is designed specifically for use with the WH II 5000 and WH II 9000 Kickspace Heaters. While it
may be used for other hydronic products, MYSON will not be responsible for compatibility.
Components:
2 - 30" braided stainless steel hoses,
1
/
2
" compression x
1
/
2
" MPT
2 - Screwdriver slot ball valves,
1
/
2
" compression x
1
/
2
" FPT
Assemble the male end of the hose to the female end of the ball valve using the recommended Loctite #565 thread
sealant. Connect the compression end of the hoses to the stub-outs on the kickspace unit. Make sure that the return
side hose is connected to the top stub-out so that air will be forced through the heat exchanger to where it can be
removed at the air vent. Connect the compression ends of the ball valves to the appropriate supply and return pipes
from the heating system.
If the heating unit is below the main or
more than 4
1
/
2
feet horizontally from the
main, install two MonoFlo tees with the
supply arrows facing each other.
Cut cabinet kick
plate so make up
air can get in.
Cut cabinet kick plate so make up
air can get in.
WH II 5000 rough opening is 18
3
/
4
"
WH II 9000 rough opening is 22
3
/
4
"
Return
Supply
ON/OFF Switch Hot Air
Cool Air IntakeCool Air Intake
Cool
Air
Intake
Cool
Air
Intake
Fan Motor
Assembly
Mounting Screws
Cabinet
Kick Plate
Cabinet
Kick Plate
Copper Pipe
Copper Pipe
Water Flow
Water Flow
Water Flow
Return
Return
Supply
12"
Keep Supply and
Return Tees 12" apart