INSTALLATION & SERVICING INSTRUCTIONS
INSTALLATION & SERVICING INSTRUCTIONS
WM15/30 BFa, WM30/40 BF, WM40/50 BF
From Serial No.
Wall Mounted Domestic Gas Fired Boiler, Natural Draught Balanced Flue
LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER.
Page 0
Page 0a
MYSON ECONOMIST WM15/30 BFa, WM30/40 BF, WM40/50 BF INSTALLATION AND
SERVICING INDEX
SECTION SUBJECT PAGE
1.0
TECHNICAL DATA 3
2.0
SAFETY 7
3.0
RANGE RATING 8
4.0
BOILER LOCATION 8
http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2102/I01-2102/I01-2102.htm (1 of 44)14/10/2004 17:30:48
Zobrazit stránku 0
1 2 3 4 5 6 ... 43 44

Shrnutí obsahu

Strany 1

INSTALLATION & SERVICING INSTRUCTIONSINSTALLATION & SERVICING INSTRUCTIONS WM15/30 BFa, WM30/40 BF, WM40/50 BFFrom Serial No.Wall Mounted Dome

Strany 2

INSTALLATION & SERVICING INSTRUCTIONSNOTE: The boilers are factory set to give the maximum heat output. 4.0 BOILER LOCATIONThe appliances are not

Strany 3

INSTALLATION & SERVICING INSTRUCTIONSPage 84.3 Positioning of Balanced Flue TerminalThe boiler is supplied with a standard flue suitable for wall

Strany 4

INSTALLATION & SERVICING INSTRUCTIONSJ From opening in a car port eg door, window into dwelling 1200mm K Vertically from a terminal on the same

Strany 5

INSTALLATION & SERVICING INSTRUCTIONSBypassThe flow through the boiler must not be allowed to fall below the figure shown in the Technical Data Se

Strany 6

INSTALLATION & SERVICING INSTRUCTIONSSome Water Authorities require a stop cock in the cold feed pipe, in which case, a combined feed and vent can

Strany 7 - Fig. 1 Dimensions

INSTALLATION & SERVICING INSTRUCTIONSFig. 4 Fully Pumped Open System - Combined Feed and Vent. (Some water authorities require a stop cock in the

Strany 8

INSTALLATION & SERVICING INSTRUCTIONSFig. 5 Fully Pumped Open System - Myson Aerjec.(Improves air removal from system).Page 12http://www.partsaren

Strany 9

INSTALLATION & SERVICING INSTRUCTIONSFig. 6 Fully Pumped Open System - Close Coupled Feed and VentMODEL VENT LENGTH A BWM 15/30 BFa 230 260WM 30

Strany 10

INSTALLATION & SERVICING INSTRUCTIONSFig. 7 Fully Pumped Sealed System Piping Diagram.Page 13CHARGE PRESSURE (BAR) 0.5 1.0 1.5Pre-pressurisation

Strany 11

INSTALLATION & SERVICING INSTRUCTIONSThe cylinder should be either an indirect type or a direct type fitted with an immersion calorifier that is s

Strany 12

INSTALLATION & SERVICING INSTRUCTIONS5.0 WATER SYSTEM 10 6.0INSTALLATION PROCEDURE 16 7.0INITIAL LIGHTING 18 8.0COMMISSIONING 19 9.0SERVICING

Strany 13

INSTALLATION & SERVICING INSTRUCTIONSFig. 8 Control Box Wiring Schematic.b - bluebr - brown gy - greyg/y- green/yellowo - orange r - redw - whiteh

Strany 14

INSTALLATION & SERVICING INSTRUCTIONSFig. 9 Function Flow Diagram.Page 156.0 INSTALLATION PROCEDUREUnpack the boiler. Remove control cover from ba

Strany 15

INSTALLATION & SERVICING INSTRUCTIONSa layer of sealant to seal between the boiler and the wallplate. Lift the boiler and pass the ductwork throug

Strany 16

INSTALLATION & SERVICING INSTRUCTIONSThe connection PUMP is for the pump live, N3 and 3 are neutral and earth connections for the pump if required

Strany 17

INSTALLATION & SERVICING INSTRUCTIONSFig. 11 Flue Duct /Terminal Assembly.. Fig. 12 View of Gas Controlshttp://www.partsarena.com/baxi/System/DATA

Strany 18

INSTALLATION & SERVICING INSTRUCTIONSPage 177.0 INITIAL LIGHTINGSee Figure 12a Check that the electricity supply and gas service cock are OFF.b Re

Strany 19

INSTALLATION & SERVICING INSTRUCTIONSthat the boiler is factory preset to give its maximum heat output.m Adjust the burner gas pressure to the fig

Strany 20

INSTALLATION & SERVICING INSTRUCTIONSopened to increase the flow rate through the boiler until the noise stops.NOTE: When the boiler is first fire

Strany 21

INSTALLATION & SERVICING INSTRUCTIONSFig. 13 Internal Layout of Boiler. http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2102/I01-21

Strany 22

INSTALLATION & SERVICING INSTRUCTIONSFig. 14 Details of Pilot Assembly.Fig. 1 5 Location of Thermostat Phial.Page 209.0 SERVICINGThis section desc

Strany 23

INSTALLATION & SERVICING INSTRUCTIONS1.0 TECHNICAL DATA RATINGSWM15/30 BFa MAXIMUM MID RANGE MINIMUMHEAT OUTPUT kW 8.8 6.6 4.4Btu/h 30,000 22,5

Strany 24 - Fig. 12 View of Gas Controls

INSTALLATION & SERVICING INSTRUCTIONS9.1.1 Removal of Outer Casing (see Figure 13)Remove the control cover by pulling forward. Remove the main cas

Strany 25

INSTALLATION & SERVICING INSTRUCTIONSIf the electrode is damaged, replace (see Section 9.2)9.1.7 Inspect the Heat Exchangera Inspect the heat exch

Strany 26

INSTALLATION & SERVICING INSTRUCTIONSPage 229.2 Replacement of Parts (see Figure 13)Please quote Boiler Serial No. when ordering spare parts.WARNI

Strany 27

INSTALLATION & SERVICING INSTRUCTIONSa Remove combustion chamber door ( see Section 9.1.2).b Unscrew the thermocouple and electrode nuts at the ba

Strany 28

INSTALLATION & SERVICING INSTRUCTIONSg Unscrew the union nut of the inlet service cock.h Remove lead from piezo generator. Remove three screws fro

Strany 29

INSTALLATION & SERVICING INSTRUCTIONSc Remove the two thermostat sensor mounting screws from the boiler flow pipe.d Disconnect the limit thermosta

Strany 30

INSTALLATION & SERVICING INSTRUCTIONSa Remove combustion chamber door ( see Section 9.1.2).b Lift the front insulation pieces to clear the bottom

Strany 31

INSTALLATION & SERVICING INSTRUCTIONSPage 2710.2 Pilot does not stay alight when gas control knob is releasedhttp://www.partsarena.com/baxi/System

Strany 32

INSTALLATION & SERVICING INSTRUCTIONSPage 28http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2102/I01-2102/I01-2102.htm (38 of 44)14

Strany 33

INSTALLATION & SERVICING INSTRUCTIONS10.3 Pilot lit, main burner will not lightPage 2910.4 Boiler shut down by limit thermostathttp://www.partsare

Strany 34

INSTALLATION & SERVICING INSTRUCTIONSWM40/50 BF 3.30 0.130 330OVERALL DIMENSIONS HEIGHT WIDTH DEPTH MODEL mm In mm In mm InW

Strany 35

INSTALLATION & SERVICING INSTRUCTIONShttp://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2102/I01-2102/I01-2102.htm (40 of 44)14/10/200

Strany 36

INSTALLATION & SERVICING INSTRUCTIONSPage 3011.0 SHORT LIST OF SPARE PARTSWM1 5/30 BFa, WM30/40 BF, WM40/50 BFKEY NO. BGC PART NO. ITEM NO. OFF

Strany 37

INSTALLATION & SERVICING INSTRUCTIONS118 397-833 Pump Overrun Boiler ThermostatType 2, Ranco C77 1 68/2021/42Page 31Page 32Page 32ahttp://www.par

Strany 38

INSTALLATION & SERVICING INSTRUCTIONShttp://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2102/I01-2102/I01-2102.htm (43 of 44)14/10/200

Strany 39

INSTALLATION & SERVICING INSTRUCTIONSPage 33http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2102/I01-2102/I01-2102.htm (44 of 44)14

Strany 40

INSTALLATION & SERVICING INSTRUCTIONSBYPASS DIAMETER 15mm diameter.GAS CONNECTION Rc 1/2 (1/2 in BSP int) WATER CONNECTION Flow 22mm compression f

Strany 41

INSTALLATION & SERVICING INSTRUCTIONSDIMENSION FOR INSTALLATION, mm (See Fig. 1)MODEL A B C D E F G H J K L M N PWM15/30 BFa 327 600 300 252 45 2

Strany 42

INSTALLATION & SERVICING INSTRUCTIONSFig. 1 Dimensionshttp://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2102/I01-2102/I01-2102.htm (7

Strany 43

INSTALLATION & SERVICING INSTRUCTIONSFig. 2 Balanced Flue Terminal PositionsFig. 3 Resistance to Water Flow through BoilerPage 62.0 SAFETYIt is es

Strany 44

INSTALLATION & SERVICING INSTRUCTIONSBS5440 Part 1, 1990 ; BS5440 Part 2, 1989; BS5449 1990; BS5546 1990; BS6798 1987; BS6891 1988; 2.2 G